All
  • All
  • Product Management
  • News and Information
  • Introduction Content
  • Corporate outlets
  • Frequently Asked Questions
  • Corporate Video
  • Corporate Portfolio
language

    Certification and Registration

    Image Name

    Quantitative compositional analysis and DMA testing capabilities

    Category:

    Quantitative compositional analysis and DMA testing capabilities


     

    Routine Quantitative Analysis

    Quantitative Analysis of Artificial Leather

    PGC-MS: Pyrolysis Gas Chromatography-Mass Spectrometry

    DSC: Differential Scanning Calorimetry

    XRF: X-ray Fluorescence Spectroscopy

    FTIR: Fourier Transform Infrared Spectroscopy

    Physical Separation Method

    Chemical Separation Method

    TGA

    High-Temperature Calcination

     

    Quantitative Analysis of Vinyl Acetate(TGA Method)

    HS/T 9-2018 Rapid Analysis Method for Vinyl Acetate Content in Ethylene-Vinyl Acetate Copolymers - Thermogravimetric Method

     

    Acrylic Acid Copolymers (EAA)

    ASTM D4094-07 Standard Test Method for Acid Content of Ethylene-Acrylic Acid Copolymers

     

    Quantitative Analysis of Fillers and Reinforced Materials

    FTIR: Fourier Transform Infrared Spectroscopy

    XRF: X-ray Fluorescence Spectroscopy

    ICP: Inductively Coupled Plasma Emission Spectrometry

    High-Temperature Calcination

    Acid Digestion

    Other Instrumental Analysis Methods

     

    Quantitative Analysis of Resins in Plastic

    PGC-MS: Pyrolysis Gas Chromatography-Mass Spectrometry

    DSC: Differential Scanning Calorimetry

    FTIR: Fourier Transform Infrared Spectroscopy

    Chemical Separation Method

    TGA

     

    Quantitative Analysis of Plastic Materials and Products, Quantitative Analysis of Rubber Raw Materials and Products, Quantitative Analysis of Adhesives and Paints and Inks

    FTIR: Fourier Transform Infrared Spectroscopy

    PGC-MS: Pyrolysis Gas Chromatography-Mass Spectrometry

    XRF: X-ray Fluorescence Spectroscopy

    Chemical Separation Method

    Physical Separation Method

     

    Label Quantitative Analysis of Product

    FTIR: Fourier Transform Infrared Spectroscopy

    PGC-MS: Pyrolysis Gas Chromatography-Mass Spectrometry

    XRF: X-ray Fluorescence Spectroscopy

    Chemical Separation Method

    Physical Separation Method

     

    Nitrogen Content

    GB/T 8088-2008 Rubber raw natural and rubber latex natural - Determination of nitrogen content

    GB/T 7766-2008 Section 5.4 Acrylonitrile monomer content in nitrile rubber
    Rubber products - Test methods for chemical analysis

     

    Quantitative Analysis of Natural Latex

    ASTM D5712-15 (Modified Lowry Method) Standard Test Method for Analysis of Aqueous Extractable Protein in Latex, Natural Rubber, and Elastomeric Products Using the Modified Lowry Method

    PGC-MS: Pyrolysis Gas Chromatography-Mass Spectrometry

    XRF: X-ray Fluorescence Spectroscopy

    FTIR: Fourier Transform Infrared Spectroscopy

    HG/T 5644-2019 Section 6.4 Latex pillows and latex protective gloves

    TGA:

    Chemical Separation Method

    Medium-Temperature Pyrolysis

    High-Temperature Calcination

     

    Quantitative Analysis of Degradable Materials

    FTIR: Fourier Transform Infrared Spectroscopy

    PGC-MS: Pyrolysis Gas Chromatography-Mass Spectrometry

    XRF: X-ray Fluorescence Spectroscopy

    Chemical Separation Method

    Physical Separation Method

     

    Starch Content

    QB/T 2957-2008 (Starch-based plastics) Determination of starch content of starch-based plastics - Thermogravimetry (TG)

     

    Quantitative Analysis of Mixed Organic Solvents

    GB/T 9722-2006 Chemical reagents - General rules for gas chromatography

     

    Quantitative Analysis of Aqueous Extractable Protein in Latex Natural Latex / Natural Rubber

    ASTM D5712-15 Standard Test Method for Analysis of Aqueous Extractable Protein in Latex, Natural Rubber, and Elastomeric Products Using the Modified Lowry Method

    ISO 12243:2003 Medical gloves made from natural rubber latex. Determination of water-extractable protein using the modified Lowry method

    GB/T 21870-2008 Medical gloves made from natural rubber latex. Determination of water-extractable protein using the modified Lowry method

     

    Isocyanate group content in polyurethane raw materials (NCO Value )

    ASTM D5155-19 Standard Test Methods for Polyurethane Raw Materials: Determination of the Isocyanate Content of Aromatic Isocyanates

    HG/T 2409-1992 

    GB/T 12009.4-2016 

    ASTM D2572-19 Standard Test Method for Isocyanate Groups in Urethane Materials or Prepolymers

     

    Standard Test Method for Hydroxyl Groups Using Reaction with p-Toluene sulfonyl Isocyanate(TSI)and Potentiometric Titration with Tetrabutylammonium Hydroxide

    ASTM E1899-16 Standard Test Method for Hydroxyl Groups Using Reaction with p-Toluene sulfonyl Isocyanate(TSI)and Potentiometric Titration with Tetrabutylammonium Hydroxide

     

    Standard Test Method for Epoxy Content of Epoxy Resins

    ASTM D1652-11Ɛ1 Standard Test Method for Epoxy Content of Epoxy Resin

     

    Comprehensive Analysis

    Comprehensive Analysis of Compositions in Plastic Products Comprehensive Analysis of Compositions in Rubber Products

    FTIR: Fourier Transform Infrared Spectroscopy

    PGC-MS: Pyrolysis Gas Chromatography-Mass Spectrometry

    XRF: X-ray Fluorescence Spectroscopy

    Chemical Separation Method

    Physical Separation Method

     

    Other Others

    Polymer Material Comparison Test

    ISO 11358-1:2014 Plastics - Thermogravimetry (TG) of polymers - General principles

    ASTM E1252-98(2013)ε1 (General method) Standard Practice for General Techniques for Obtaining Infrared Spectra for Qualitative Analysis

    ISO 4650:2012 (Rubber) Rubber - Identification - Infrared spectrometric methods

    ISO 11357-3:2018 (Plastics) Plastics - Differential scanning calorimetry (DSC) - Part 3: Determination of temperature and enthalpy of melting and crystallization

    ISO 11357-2:2020 Plastics - Differential scanning calorimetry (DSC) - Part 2: Determination of glass transition temperature and step height

     

    Fracture Analysis

    SEM: Scanning Electron Microscopy

    EDS: Energy Dispersive X-Ray Spectroscopy

     

    Element Analysis

    EDS: Energy Dispersive X-Ray Spectroscopy

    SEM: Scanning Electron Microscopy

     

    Molecular Weight of Polymer and Polymer Dispersity Index

    GB/T 21863-2008 Gel permeation chromatography (GPC) - Tetrahydrofuran as elution solvent

    ISO 13885-1:2020 Gel permeation chromatography (GPC) - Part 1: Tetrahydrofuran (THF) as eluent

     

    DMA Testing Capability

    Plastics: Dynamic Mechanical Properties

    ISO 6721-4:2019 Plastics - Determination of dynamic mechanical properties - Part 4: Tensile vibration - Non-resonance method

    ASTM D5024-15 Standard Test Method for Plastics: Dynamic Mechanical Properties: In Compression

    ASTM D5418-15 Standard Test Method for Plastics: Dynamic Mechanical Properties: In Flexure (Dual Cantilever Beam)

    ASTM D4065-12 Standard Practice for Plastics: Dynamic Mechanical Properties: Determination and Report of Procedures

    ISO 6721-1:2019 Plastics - Determination of dynamic mechanical properties - Part 1: General principles

    ASTM D5023-15 Standard Test Method for Plastics: Dynamic Mechanical Properties: In Flexure (Three-Point Bending)

    ISO 6721-5:2019 Plastics - Determination of dynamic mechanical properties - Part 5: Flexural vibration - Non-resonance method

    ASTM D5026-15 Standard Test Method for Plastics: Dynamic Mechanical Properties: In Tension

     

    DMA Tg Testing

    ASTM E1640-18 Standard Test Method for Assignment of the Glass Transition Temperature by Dynamic Mechanical Analysis

    ISO 6721-11:2019 Plastics - Determination of dynamic mechanical properties - Part 11: Glass transition temperature

    GB/T 4722-2017 Section 6.7.2 Test methods for rigid copper clad laminates for printed circuit boards

    ASTM D5418-15 Standard Test Method for Plastics: Dynamic Mechanical Properties: In Flexure (Dual Cantilever Beam)

    ASTM D7028-07(R2015) Standard Test Method for Glass Transition Temperature (DMA Tg) of Polymer Matrix Composites by Dynamic Mechanical Analysis (DMA)


    Previous page

    Next page

    Previous page

    Next page

    Related Information